SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
---|---|---|---|---|---|---|---|---|---|---|---|
No stock item (MOQ) | 404309 | Durostone® EPM 204 pressed | sheet | sheet | 1.900 x 1.000 x 8 (+/-0,7) mm | 1,900 mm | 1,000 mm | 8 mm | |||
No stock item (MOQ) | 420102 | Durostone® EPM 204 pressed | sheet | sheet | 1.900 x 1.000 x 25 (+/-1,4) mm | 1,900 mm | 1,000 mm | 25 mm | |||
No stock item (MOQ) | 444517 | Durostone® EPM 204 pressed | sheet | sheet | 1.900 x 1.000 x 15 (+/-1,1) mm | 1,900 mm | 1,000 mm | 15 mm | |||
No stock item (MOQ) | 449380 | Durostone® EPM 204 pressed | sheet | sheet | 1.900 x 1.000 x 10 (+/-0,8) mm | 1,900 mm | 1,000 mm | 10 mm | |||
No stock item (MOQ) | 449863 | Durostone® EPM 204 pressed | sheet | sheet | 1.900 x 1.000 x 27 (+/-1,45) mm | 1,900 mm | 1,000 mm | 27 mm |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flexural strength ┴ | ISO 178 | MPa | 360 |
Flexural strength ┴ +150°C | ISO 178 | MPa | 200 |
Modulus of elasticity in flexion ┴ | ISO 178 | MPa | 18000 |
Modulus of elasticity in flexion ┴ +150°C | ISO 178 | MPa | 12000 |
Compressive strength ┴ | ISO 604 | MPa | 450 |
Compressive strength II | ISO 604 | MPa | 300 |
Tensile strength II | ISO 527 | MPa | 280 |
Impact strength II (Charpy) | ISO 179 | kJ / m2 | 120 |
Shear strength ┴ | IEC 60893 | MPa | 150 |
Shear strength II | IEC 60893 | MPa | 25 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Temperature index | IEC 60216 | T.I. | 180 |
Coefficient of linear expansion ┴ | NF T 51221 | 10-6 x K-1 | 13 |
Coefficient of linear expansion II | NF T 51221 | 10-6 x K-1 | 65 |
Temperature of deflection under load | IEC 893-2 | °C | > 200 |
Thermal conductivity | ISO 8302 | W/m K | 0,36 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flammability | NF P92-507 | - | M1 |
Flammability | UL94 | V0 | |
Smoke index | NF P 92501 | - | F1 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ISO 1183 | g / cm3 | 1,9 |
Water absorption (10mm thickness) | ISO 62 | % | 0,20 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 12 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 60 |
Relative permittivity (50 Hz) | IEC 60250 | εr | 5 |
Dielectric loss factor (50 Hz) | IEC 60250 | tan δ | 0,05 |
Specific surface resistance | IEC 60093 | Ω | 1012 |
Specific volume resistance | IEC 60093 | Ω x cm | 1013 |
Comparative tracking index | IEC 60112 | CTI | 400 |