Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,52 |
Water absorption | DIN EN ISO 62 | % | 0,7 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB / HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 50 |
Elongation at break | DIN EN ISO 527 | % | 16 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2500 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 4 |
Shore hardness | DIN EN ISO 868 | scale D | 80 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 165 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 120 |
Service temperature, long term | Average | °C | -50 … 100 |
Service temperature, short term (max.) | Average | °C | 140 |
Heat deflection temperature | DIN EN ISO 75, Verf. A, HDT | °C | 98 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 3,7 | |
Dielectric dissipation factor (50 Hz) | IEC 60250 | 0,002 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1015 |
Comparative tracking index | IEC 60112 | 600 | |
Dielectric strength | IEC 60243 | kV / mm | 33 |