Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,47 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Elongation at break | DIN EN ISO 527 | % | 1 |
Tensile strength | DIN EN ISO 527 | MPa | 50 |
Impact strength | DIN EN ISO 179 | kJ / m2 | 6 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 2 |
Ball indentation hardness | DIN EN ISO 2039-1 | MPa | 231 |
Shore hardness | DIN EN ISO 868 / 15 sek | scale D | 82 |
Compressive strength | DIN EN ISO 604 | MPa | 3800 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 342 |