Glastherm® HT LC boasts extremely low thermal conductivity, providing excellent insulation properties even with very thin wall thicknesses. Glastherm® HT LC is free of asbestos and can be easily cut and adapted with standard metal tools.
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ISO 1183 | g / cm3 | 1,5 |
Flexural strength ┴ | ISO 178 | MPa | 170 |
Modulus of elasticity in flexion ┴ | ISO 178 | MPa | 10000 |
Compressive strength 1)┴ | ISO 604 | MPa | 300 |
Compressive strength 1)┴ +200°C | ISO 604 | MPa | 90 |
Impact strength ┴ (Charpy) | ISO 179 | kJ / m2 | 80 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal conductivity 2)┴ | W / (m * K) | 0,18 | |
Coefficient of linear expansion II | TMA (Mettler) | 10-6 x K-1 | ≈ 20 |
Max. continuous operating temperature | °C | 200 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Water absorption (4mm thickness) | ISO 62 | % | 0,2 |