SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
---|---|---|---|---|---|---|---|---|---|---|---|
No stock item (MOQ) | 101361 | Polystone® PVDF GK natural extruded | sheet | sheet | natural | 3.000 x 1.500 x 4 mm | 3 000 mm | 1 500 mm | 4 mm | ||
No stock item (MOQ) | 229622 | Polystone® PVDF GK natural extruded | sheet | sheet | natural | 3.000 x 1.500 x 6 mm | 3 000 mm | 1 500 mm | 6 mm | ||
No stock item (MOQ) | 375606 | Polystone® PVDF GK natural extruded | sheet | sheet | natural | 3.000 x 1.500 x 3 mm | 3 000 mm | 1 500 mm | 3 mm | ||
No stock item (MOQ) | 412775 | Polystone® PVDF GK natural extruded | sheet | sheet | natural | 3.000 x 1.500 x 4 mm | 3 000 mm | 1 500 mm | 4 mm |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | >1,75 |
Water absorption | DIN EN ISO 62 | % | 0,4 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | >50 |
Elongation at break | DIN EN ISO 527 | % | >30 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >2100 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | >13 |
Shore hardness | DIN EN ISO 868 | scale D | >75 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 172 ... 175 |
Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,19 |
Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,20 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 100 ... 140 |
Service temperature, long term | Average | °C | 0 … 140 |
Service temperature, short term (max.) | Average | °C | >145 |
Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 140 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 8,0 | |
Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1014 |
Surface resistivity | DIN EN 62631-3-2 | Ω | >1014 |
Comparative tracking index | IEC 60112 | 600 | |
Dielectric strength | IEC 60243 | kV / mm | 20 |