Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,45 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 / V0 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 45 |
Elongation at break | DIN EN ISO 527 | % | 15 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 3000 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 2 |
Shore hardness | DIN EN ISO 868 | scale D | 79 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,2 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 80 |
Service temperature, long term | Average | °C | 0 … 60 |
Service temperature, short term (max.) | Average | °C | 70 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 3 | |
Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1015 |
Surface resistivity | DIN EN 62631-3-2 | Ω | 1013 |