In addition to its good hot steam sterilizability, this special material has good machinability and excellent chemical resistance. Polystone® P HG EHS is an isotactic, highly heat-stabilized polypropylene that is available as a homopolymer. This unique property profile makes it perfect for components for respiratory equipment or for applications in the pharmaceutical industry, either as a distribution unit, components for drug production or in chromatography.
We are a system supplier and partner from the idea to the OEM's end product - as a cooperative value contribution. We are able to support the healthcare industry at the highest level.
Industry Manager Healthcare - Mail: AReuner@roechling.com
SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
---|---|---|---|---|---|---|---|---|---|---|---|
No stock item (MOQ) | 492464 | Polystone® P HG EHS black pressed | sheet | sheet | black, similar RAL 9005 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | >0,91 |
Water absorption | DIN EN ISO 62 | % | 0,10 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB / HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | >30 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >1800 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | >4 |
Shore hardness | DIN EN ISO 868 | scale D | >70 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 162 ... 167 |
Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,20 |
Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,70 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 120 ... 190 |
Heat deflection temperature | DIN EN ISO 75, Verf. A, HDT | °C | 90 |
Autoclaving temperature resistance | Average | °C | 0 ... 135 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1014 |
Surface resistivity | DIN EN 62631-3-2 | Ω | >1014 |
Dielectric strength | IEC 60243 | kV / mm | >40 |