Durostone® or Glastic® composite profiles offer several advantages in comparison to other materials:
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,9 - 2,1 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flexural strength, lengthwise | ISO 178 | MPa | > 170 |
Flexural modulus, lengthwise | ISO 178 | MPa | > 17.000 |
Tensile strength, lengthwise | ISO 527 | MPa | > 170 |
Tensile modulus, lengthwise | ISO 527 | MPa | > 17.000 |
Compressive strength, perpendicular | ISO 14126 | MPa | > 50 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Temperature index | IEC 60216 | T.I. | F (155 °C) |
Glass transition temperature | DMA | °C | > 120 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flammability | EN45545 Version 2020 | HL3 R22/R23 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Comparative tracking index | IEC 60112 | CTI | 600 |