Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,14 |
Water absorption | DIN EN ISO 62 | % | 2,4 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB / HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 70 |
Elongation at break | DIN EN ISO 527 | % | 50 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2900 |
Shore hardness | DIN EN ISO 868 | scale D | 80 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 210 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 80 |
Service temperature, long term | Average | °C | -40 … 100 |
Service temperature, short term (max.) | Average | °C | 160 |
Heat deflection temperature | DIN EN ISO 75, Verf. A, HDT | °C | 90 |