Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,41 |
Water absorption | DIN EN ISO 62 | % | 0,20 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 48 |
Elongation at break | DIN EN ISO 527 | % | 20 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2500 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 8 |
Shore hardness | DIN EN ISO 868 | scale D | 77 |
Ball indentation hardness | DIN EN ISO 2039-1 | MPa | 100 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal conductivity | DIN EN ISO 8302 | W / (m * K) | 0,16 |
Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 75 |
Service Temperature | °C | -20 ... +60 | |
Heat deflection temperature | DIN EN ISO 75 | °C | 70 |
Coefficient of linear thermal expansion | DIN EN ISO 11359-2 | mm/m K | ∼ 0,075 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 3,2 | |
Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1015 |
Surface resistivity | DIN EN 62631-3-2 | Ω | >1013 |