IT

Scegliere una lingua

 

Durostone® UPM S2

GFK-UP

Durostone® UPM S2 è un materiale plastico fibrorinforzato con elevate proprietà meccaniche. Questo materiale ha un’infiammabilità definita. Il rinforzo in fibra viene effettuato con una stuoia o un tessuto di fibre di vetro (VTR).

raspberry red, similar RAL 3027cream, similar RAL 9001
sheet
QR-Code

Characteristics

  • Special vinyl ester (VE) resin matrix reinforced with a combination of an e-glass roving mat and fabric
  • SMC high-pressure laminate
  • High mechanical strength
  • High dielectric strength

Technical Specifications Durostone® UPM S2 red

Test MethodUnitGuideline Value
DensityISO 1183g / cm31,95
Flexural strength 1)ISO 178MPa350
Flexural strength 1) +130°CISO 178MPa175
Modulus of elasticity in flexion 1)ISO 178MPa18000
Modulus of elasticity in flexion 1) +130°CISO 178MPa12000
Compressive strength ISO 604MPa480
Tensile strength IIISO 527MPa220
Impact strength II (Charpy)ISO 179kJ / m2200
Test MethodUnitGuideline Value
FlammabilityUL 94/V0 / 5mm
Smoke density & toxicity, classNF F 16-101/F0
Fire test, classNF P 92-501/M2
Temperature indexIEC 60216T.I.155
Insulation classIEC 60085/F
Test MethodUnitGuideline Value
Water absorption (4mm thickness)ISO 62% 0,5
Test MethodUnitGuideline Value
Electric strength 90°C under oil IEC 60243kV / mm12
Electric strength 90°C under oil IIIEC 60243kV/25mm75
Relative permittivity (50 Hz)IEC 60250εr4
Dielectric loss factor (50 Hz)IEC 60250tan δ0,01
Specific surface resistanceIEC 60093Ω1010
Comparative tracking indexIEC 60112CTI600

Technical Specifications Durostone® UPM S2 white

Test MethodUnitGuideline Value
DensityISO 1183g / cm31,95
Flexural strength 1)ISO 178MPa350
Flexural strength 1) +130°CISO 178MPa175
Modulus of elasticity in flexion 1)ISO 178MPa18000
Modulus of elasticity in flexion 1) +130°CISO 178MPa12000
Compressive strength ISO 604MPa480
Tensile strength IIISO 527MPa220
Impact strength II (Charpy)ISO 179kJ / m2200
Test MethodUnitGuideline Value
FlammabilityUL 94/V0 / 5mm
Smoke density & toxicity, classNF F 16-101/F0
Fire test, classNF P 92-501/M2
Temperature indexIEC 60216T.I.155
Insulation classIEC 60085/F
Test MethodUnitGuideline Value
Water absorption (4mm thickness)ISO 62% 0,5
Test MethodUnitGuideline Value
Electric strength 90°C under oil IEC 60243kV / mm12
Electric strength 90°C under oil IIIEC 60243kV/25mm75
Relative permittivity (50 Hz)IEC 60250εr4
Dielectric loss factor (50 Hz)IEC 60250tan δ0,01
Specific surface resistanceIEC 60093Ω1010
Comparative tracking indexIEC 60112CTI600