Our PVDF HG was developed for the demanding requirements of the healthcare industry. It is a material of the highest purity with excellent UV resistance and sterilizability. With its good or balanced combination of toughness, chemical resistance and strength, PVDF ensures reliable performance in many demanding applications such as in the pharmaceutical industry either as a distribution unit or in drug manufacturing. The temperature stability in continuous use is up to 140 °C.
We are a system supplier and partner from the idea to the OEM's end product - as a cooperative value contribution. We are able to support the healthcare industry at the highest level.
Industry Manager Healthcare - Mail: AReuner@roechling.com
SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
---|---|---|---|---|---|---|---|---|---|---|---|
No stock item (MOQ) | 500878 | Polystone® PVDF HG natural pressed | sheet | sheet | natural | 2.000 x 1.000 x 30 mm | 2.000 mm | 1.000 mm | 30 mm | ||
No stock item (MOQ) | 500880 | Polystone® PVDF HG natural pressed | sheet | sheet | natural | 2.000 x 1.000 x 50 mm | 2.000 mm | 1.000 mm | 50 mm |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | >1,75 |
Water absorption | DIN EN ISO 62 | % | 0,4 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | >50 |
Elongation at break | DIN EN ISO 527 | % | >30 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >2100 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | >13 |
Shore hardness | DIN EN ISO 868 | scale D | >75 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 172 ... 175 |
Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,19 |
Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,20 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 100 ... 140 |
Service temperature, long term | Average | °C | 0 ... 140 |
Service temperature, short term (max.) | Average | °C | >145 |
Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 140 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 8,0 | |
Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1014 |
Surface resistivity | DIN EN 62631-3-2 | Ω | >1014 |
Comparative tracking index | IEC 60112 | 600 | |
Dielectric strength | IEC 60243 | kV / mm | 20 |