Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | ISO 1183 | g / cm3 | 2,1 |
Flexural strength ┴ | ISO 178 | MPa | 700 |
Flexural strength ┴ +150°C | ISO 178 | MPa | 350 |
Modulus of elasticity in flexion ┴ | ISO 178 | MPa | 35000 |
Compressive strength (tangential) | ISO 604 | MPa | 500 |
Compresive strength (axial) | ISO 604 | MPa | 110 |
Compressive strength (radial) | ISO 604 | MPa | 110 |
Tensile strength II | ISO 527 | MPa | 800 |
Impact strength (radial) | ISO 179 | kJ / m2 | 250 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal conductivity ┴ | W / (m * K) | ≈ 0,35 | |
Temperature index | IEC 60216 | T.I. | 180 |
Insulation class | IEC 60085 | / | H |
TG-Value | DSC | °C | 150 |
Coefficient of linear expansion (tangential) | TMA | 10-6 x K-1 | 5 - 10 |
coefficient of linear expansion (axial) | TMA | 10-6 x K-1 | 20 - 30 |
coefficient of linear expansion (radial) | TMA | 10-6 x K-1 | 25 - 40 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 5 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 35 |
Relative permittivity (50 Hz) | IEC 60250 | εr | ≈ 5 |
Dielectric loss factor (50 Hz) | IEC 60250 | tan δ | ≈ 0,03 |
Insulation resistance after 24 h water immersion | IEC 60167 | Ω | 5 x 109 |
Comparative tracking index | EN 60112 | CTI | 225 |