Durostone® UPM S2 est un composite renforcé de fibres avec d’excellentes propriétés mécaniques. Ce composite présente une résistance au feu mesurée. Le renforcement de fibres se fait avec un mat de verre ou avec un tissu de verre (GFK).
Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | ISO 1183 | g / cm3 | 1,95 |
Flexural strength 1)┴ | ISO 178 | MPa | 350 |
Flexural strength 1)┴ +130°C | ISO 178 | MPa | 175 |
Modulus of elasticity in flexion 1)┴ | ISO 178 | MPa | 18000 |
Modulus of elasticity in flexion 1)┴ +130°C | ISO 178 | MPa | 12000 |
Compressive strength ┴ | ISO 604 | MPa | 480 |
Tensile strength II | ISO 527 | MPa | 220 |
Impact strength II (Charpy) | ISO 179 | kJ / m2 | 200 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flammability | UL 94 | / | V0 / 5mm |
Smoke density & toxicity, class | NF F 16-101 | / | F0 |
Fire test, class | NF P 92-501 | / | M2 |
Temperature index | IEC 60216 | T.I. | 155 |
Insulation class | IEC 60085 | / | F |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Water absorption (4mm thickness) | ISO 62 | % | 0,5 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 12 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 75 |
Relative permittivity (50 Hz) | IEC 60250 | εr | 4 |
Dielectric loss factor (50 Hz) | IEC 60250 | tan δ | 0,01 |
Specific surface resistance | IEC 60093 | Ω | 1010 |
Comparative tracking index | IEC 60112 | CTI | 600 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | ISO 1183 | g / cm3 | 1,95 |
Flexural strength 1)┴ | ISO 178 | MPa | 350 |
Flexural strength 1)┴ +130°C | ISO 178 | MPa | 175 |
Modulus of elasticity in flexion 1)┴ | ISO 178 | MPa | 18000 |
Modulus of elasticity in flexion 1)┴ +130°C | ISO 178 | MPa | 12000 |
Compressive strength ┴ | ISO 604 | MPa | 480 |
Tensile strength II | ISO 527 | MPa | 220 |
Impact strength II (Charpy) | ISO 179 | kJ / m2 | 200 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flammability | UL 94 | / | V0 / 5mm |
Smoke density & toxicity, class | NF F 16-101 | / | F0 |
Fire test, class | NF P 92-501 | / | M2 |
Temperature index | IEC 60216 | T.I. | 155 |
Insulation class | IEC 60085 | / | F |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Water absorption (4mm thickness) | ISO 62 | % | 0,5 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 12 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 75 |
Relative permittivity (50 Hz) | IEC 60250 | εr | 4 |
Dielectric loss factor (50 Hz) | IEC 60250 | tan δ | 0,01 |
Specific surface resistance | IEC 60093 | Ω | 1010 |
Comparative tracking index | IEC 60112 | CTI | 600 |