Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | ISO 1183 | g / cm3 | 1,95 |
Flexural strength ┴ | ISO 178 | MPa | 470 |
Modulus of elasticity in flexion ┴ | ISO 178 | MPa | 25000 |
Compressive strength ┴ | ISO 604 | MPa | 450 |
Compressive strength II | ISO 604 | MPa | 250 |
Tensile strength II | ISO 527 | MPa | 400 |
Impact strength II (Charpy) | ISO 179 | kJ / m2 | 200 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Temperature index | IEC 60216 | T.I. | 155 |
Insulation class | IEC 60085 | / | F |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Water absorption (4mm thickness) | ISO 62 | % | 0,1 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 15 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 75 |
Relative permittivity (50 Hz) | IEC 60250 | εr | ≈ 5 |
Specific surface resistance | IEC 60093 | Ω | 1010 |
Comparative tracking index | IEC 60112 | CTI | 600 |