In addition to its good hot steam sterilizability, this special material has good machinability and excellent chemical resistance. Polystone® P HG HI is a copolymer with increased impact strength. This unique property profile makes it perfect for components for respiratory equipment or for applications in the pharmaceutical industry, either as a distribution unit, components for drug production or in chromatography.

noir, similaire RAL 9005
plaque
QR-Code

Characteristics

  • Good impact strength
  • High rigidity
  • ISO 10993-5 tested on semi-finished product
  • Corrosion resistant
  • Chemical resistant

Industries

Application Examples

Applications pour centrifugeuse

Résistance élevée et résistance à la chaleur Faible poids Impact élevé Matériau typique Polystone® P HG HI (noir)


We are a system supplier and partner from the idea to the OEM's end product - as a cooperative value contribution. We are able to support the healthcare industry at the highest level.

Industry Manager Healthcare - Mail: AReuner@roechling.com


Variants

SKUNameTypeTypeColorMeasurementsLengthWidthThicknessHeight
No stock item (MOQ)
486541Polystone® P HG HI black pressed plaque plaque noir, similaire RAL 9005

Technical Specifications Polystone® P HG HI black

Test MethodUnitGuideline Value
DensitéDIN EN ISO 1183-1g / cm3>0,90
Water absorptionDIN EN ISO 62%0,1
Flammability (Thickness 3 mm / 6 mm)UL 94HB
Test MethodUnitGuideline Value
Yield stressDIN EN ISO 527MPa>30
Elongation at breakDIN EN ISO 527%>50
Tensile modulus of elasticityDIN EN ISO 527MPa>1500
Notched impact strengthDIN EN ISO 179kJ / m2>30
Shore hardnessDIN EN ISO 868scale D>70
Test MethodUnitGuideline Value
Melting temperatureISO 11357-3°C162 ... 167
Thermal conductivityDIN 52612-1W / (m * K)0,20
Thermal capacityDIN 52612kJ / (kg * K)1,70
Coefficient of linear thermal expansionDIN 5375210-6 / K120 ... 190
Service temperature, long termAverage°C0 ... 100
Service temperature, short term (max.)Average°C150
Vicat softening temperatureDIN EN ISO 306, Vicat B°C95
Test MethodUnitGuideline Value
Volume resistivityDIN EN 62631-3-1Ω * cm>1014
Surface resistivityDIN EN 62631-3-2Ω>1014
Dielectric strengthIEC 60243kV / mm>40

Contact

Vous avez la possibilité de joindre des fichiers à votre message. Les fichiers doivent être des documents JPEG, PNG, BMP, PDF. Veuillez vous assurer que vous ajoutez uniquement des fichiers de moins de 8 Mo

Information on data protection can be found here.

renouveler
 
Search

Refine Results

Contact

Share

Newsletter Registration

Select Website

Roechling_Industrial_Banner.jpg
Plastiques pour applications techniques

Industrial