Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | DIN EN ISO 1183-1 | g / cm3 | 1,04 |
Water absorption | DIN EN ISO 62 | % | 0,2 – 0,3 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 21 |
Elongation at break | DIN EN ISO 527 | % | 60 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 1850 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 10 |
Shore hardness | DIN EN ISO 868 | scale D | 80 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Température de transistion vitreuse | ISO 11357-3 | °C | 95 – 100 |
Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,18 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 70 |
Service temperature, long term | Average | °C | -10 … 80 |
Service temperature, short term (max.) | Average | °C | 75 – 90 |
Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 99 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | IEC 60250 | 2,50 | |
Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,0004 | |
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1016 |
Surface resistivity | DIN EN 62631-3-2 | Ω | >1015 |
Dielectric strength | IEC 60243 | kV / mm | 40 |