Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,58 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Elongation at break | DIN EN ISO 527 | % | 2 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 5000 |
Tensile strength | DIN EN ISO 527 | MPa | 50 |
Shore hardness | DIN EN ISO 868 | scale D | 80 |
Ball indentation hardness | DIN EN ISO 2039-1 | MPa | 200 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Temp. of deflection under load, 1.80 MPa | ISO 75-1/-2 | °C | 325 |
Temp. of deflection under load, 0.45 MPa | ISO 75-1/-2 | °C | 358 |