Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | DIN EN ISO 1183-1 | g / cm3 | 1,38 |
Water absorption | DIN EN ISO 62 | % | 0,0 |
Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 / V0 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 50 |
Elongation at break | DIN EN ISO 527 | % | 4 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 3000 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 5,0 |
Shore hardness | DIN EN ISO 868 | scale D | 77 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Melting temperature | ISO 11357-3 | °C | 285 |
Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 50 |
Service temperature, long term | Average | °C | -20 … 220 |
Service temperature, short term (max.) | Average | °C | 260 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1016 |
Surface resistivity | DIN EN 62631-3-2 | Ω | 1013 |