| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Densité | DIN EN ISO 1183-1 | g / cm3 | >0,96 |
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB | |
| Flammability (Thickness 3 - 10 mm) | DIN 4102 | B2 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | >25 |
| Elongation at yield stress | DIN EN ISO 527 | % | >8 |
| Elongation at break | DIN EN ISO 527 | % | >235 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >1200 |
| Notched impact strength | DIN EN ISO 11542 | / | |
| Notched impact strength, RT | DIN EN ISO 179 EA1 | kJ / m2 | >4 |
| Notched impact strength, 0°C | DIN EN ISO 179 EA1 | kJ / m2 | >3 |
| Shore hardness | DIN EN ISO 868 | scale D | >60 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 130 ... 135 |
| Température de transistion vitreuse | ISO 11357-3 | °C | ∼ -60 |
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,40 |
| Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,90 |
| Service temperature, long term | Average | °C | -30 … 80 |
| Heat storage behavior lengthwise | ISO 14632 | % | 0,05 |
| Heat storage behavior crosswise | ISO 14632 | % | 0,04 |