Test Method | Unit | Guideline Value | |
---|---|---|---|
Standard Color | Light Beige | ||
Maximum Service Temp. | °C | 350 | |
Continuous Use Temp. | °C | 220 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flexural Strength | ASTM D 790 | psi | 52,200 |
Compressive Strength @302°F / 150°C | ASTM D 695 | psi | 55,100 |
Compressive Strength @392°F / 200°C | ASTM D 695 | psi | 40,600 |
Compressive Strength @550°F / 288°C | ASTM D 695 | psi | 35,000 |
Compressive Strength @RT | ASTM D 695 | psi | 72,500 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Coefficient of Thermal Expansion Across Thickness | ASTM D 696 | (in./in.°C) x 10-5 | 5.7 |
Coefficient of Thermal Expansion Across Surface | ASTM D 696 | (in./in.°C) x 10-5 | 1.3 |
Thermal Conductivity | ASTM C 177 | BTUIn/HrFt2 °F | 1.75 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D 792 | lbs/ft3 | 115 |
Water Absorption | ASTM D 570 | % by wt. | 0.2 |
Thickness Tolerance | inches | +/-0.004 |