Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D792 | g / cm3 | 1.33 |
Water Absorption 24 hours | ASTM D570 | % | 1.0 |
Dissipation Factor | ASTM D150 | 1MHz | 0.005 |
Water Absorption Saturation | ASTM D570 | % | 2.0 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Hardness | ASTM D2240 | Shore D | 86 |
Tensile Strength at yield 73°F | ASTM D638 | psi | 11000 |
Tensile Modulus | ASTM D638 | psi | 425000 |
Elongation at Break | ASTM D638 | % | 30 |
Flexural Strength | ASTM D790 | psi | 18000 |
Flexural Modulus | ASTM D790 | psi | 450000 |
Compressive Strength | ASTM D695 | psi | 8,000 |
Rockwell Hardness | ASTM D785 | 86 | |
Rockwell Hardness | ASTM D785 | R | 120 |
Shear Strength | ASTM D732 | psi | 6,000 |
Izod Impact, Notched | ASTM D256 | ft-lb/in | 1.0-1.8 |
Coefficient of Friction, Dynamic | 0.2 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal Conductivity | in/hr/ft2 /°F | 1.7 | |
Coefficient of Linear Thermal Expansion | ASTM D696 | in/in/°F x10-5 | 4.8 |
Melting Point | °F | 330 | |
Continuous Service Temperature, Air | °F | 180 | |
Deflection Temperature at 1.8Mpa (264psi) | ASTM D648 | °F | 250 |
Flammability, UL94 | 1/8 inch | HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | ASTM D150 | 1MHz | 3.7 |
Dielectric strength | ASTM D149 | V/mil | 400 |
Surface resistivity | ASTM D257 | Ω/cm | 109-10^11 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
FDA | No | ||
NSF | No | ||
USDA | No |