Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D792 | g / cm3 | 1.54 |
Water Absorption | ASTM D570 | % | 0.8 |
Water Absorption 24 hours | ASTM D570 | % | 0.2 |
Dissipation Factor | ASTM D150 | 1MHz | 0.009 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Tensile Strength at Yield | ASTM D638 | psi | 6630 |
Hardness | ASTM D2240 | Shore D | 76 |
Tensile Modulus | ASTM D638 | psi | 540000 |
Tensile Elongation | ASTM D638 | % | 30 |
Flexural Strength | ASTM D790 | psi | 12500 |
Flexural Modulus | ASTM D790 | psi | 405000 |
Compressive Strength | ASTM D695 | psi | 12600 |
Rockwell Hardness | ASTM D785 | 50 | |
Rockwell Hardness | ASTM D785 | R | 110 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal Conductivity | in/hr/ft2 /°F | 2.0 | |
Coefficient of Linear Thermal Expansion | ASTM D696 | in/in/°F x10-5 | 4.4 |
Melting Point | ASTM D789 | °F | 350 |
Continuous Service Temperature, Air | °F | 185 | |
Deflection Temperature at 1.8Mpa (264psi) | ASTM D648 | °F | 244 |
Deflection Temperature at 1.8Mpa (66psi) | ASTM D648 | °F | 334 |
Flammability, UL94 | 1/8 inch | HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | ASTM D150 | 1MHz | 3.1 |
Dielectric strength | ASTM D149 | V/mil | 400 |
Surface resistivity | ASTM D257 | Ω/cm | 1016 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
FDA | No | ||
NSF | No | ||
USDA | No |