Our premium material EtroX® I CM was specially developed to meet the high demands of the electronics, aerospace and automotive industries. As a pure polyimide, it withstands particularly high temperatures. EtroX® I CM can be used to design components that offer significant advantages over other thermoplastics.
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | 1,37 |
| Water absorption | DIN EN ISO 62 (23°C / 24h) | % | 0,6 |
| Water absorption | DIN EN ISO 62 (23°C / 48h) | % | 0,8 |
| Water absorption | DIN EN ISO 62 (23°C / 3 Weeks) | % | 2,4 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Elongation at break | DIN EN ISO 527 | % | 8 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 3600 |
| Tensile strength | DIN EN ISO 527 | MPa | 145 |
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | 10 |
| Shore hardness | DIN EN ISO 868 | scale D | 89 |
| Ball indentation hardness | DIN EN ISO 2039-1 | MPa | 240 |
| Elastic modulus of compression | DIN EN ISO 604 | MPa | 4200 |
| Tensile creep modulus, 1h | ISO 899-1 | MPa | 3390 |
| Tensile creep modulus, 1000h | ISO 899-1 | MPa | 2730 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Glass transition temperature | ISO 11357-3 | °C | 323 |
| Service temperature, short term (max.) | Average | °C | 380 |
| Mean coefficient of linear thermal expansion | ISO 11359-2 | K-1 | 41 |
| Heat deflection temperature | DIN EN ISO 75 | °C | 319 |
| Temp. of deflection under load, 1.80 MPa | ISO 75-1/-2 | °C | 319 |
| Temp. of deflection under load, 0.45 MPa | ISO 75-1/-2 | °C | 343 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | > 1015 |
| Dielectric constant @ 100Hz | IEC 60250 | 4,2 | |
| Dielectric constant @ 1kHz | IEC 60250 | 4,2 | |
| Dielectric constant @ 10kHz | IEC 60250 | 4,1 | |
| Dielectric constant @ 100 kHz | IEC 60250 | 4,1 | |
| Dielectric constant @ 10GHz | IEC 61189-2-721 | 3,4 | |
| Dielectric constant @ 40GHz | IEC 61189-2-721 | 3,3 | |
| Dielectric constant @ 100GHz | IEC 61189-2-721 | 3,2 | |
| Specific Volume resistivity | IEC 60093 | Ωm | 8*1013 |
| Specific Surface resistivity | IEC 60093 | Ω | 5*1015 |
| Relative permittivity, 100Hz | IEC 62631-2-1 | - | 3,5 |
| Relative permittivity, 1MHz | IEC 62631-2-1 | - | 3,4 |
| Dissipation factor, 1 MHz | IEC 62631-2-1 | E-4 | 80 |
| Electric strength | IEC 60243-1 | kV / mm | 34 |